IONTOPHORESIS PROCEDURE

IMPORTANT: See Phoresor System and electrode in­struction guides for indications, contraindications, warn­ings, precautions and directions for use.

1.                 Clean skin is absolutely necessary to minimize or eliminate skin irritation. Clean both electrode sites vigorously with an alcohol wipe prior to applying electrodes to remove dry skin, salts and oils. Excess hair may be trimmed with scissors or electric clippers. Do not shave skin. Doing so may result in excessive irritation or burns.

2.        Prepare electrodes following package instructions.

3.        Place the drug electrode over the point of deep tender­ness.

4.        The dispersive pad may be placed proximal or distal to the drug electrode over a major muscle (e.g.. quadri­ceps). Never tape, bind or compress either electrode in any way. Properly prepared drug electrodes and dispersive pads do not require added fixation on prop­erly prepared skin.

5.        Do not allow patient to extend or flex the hip or knee or to press on. or lean against, electrodes during treat­ment. This prevents circuit breaks and minimizes the possibility of excessive skin irritation or burns.

6.        Set treatment dosage for 24 to 40 milliampere-minutes according to package instructions (for TransQ® elec­trodes) depending on medications chosen. Use lower current and/or shorter treatment times for patients with sensitive skin.

7.        Treat every other day. Usually, no more than three to six treatments are required, however, additional treat­ments are not contraindicated.

IOGEL® Disposable Electrodes - Large (3.5cc fill)

$64.00

IOGEL® Disposable Electrodes - Large (3.5cc fill)

IOGEL® Disposable Electrodes - Medium (2.5cc fill)

$64.00

IOGEL® Disposable Electrodes - Medium (2.5cc fill)

IOGEL® Disposable Electrodes - Small (1.5cc fill)

$64.00

IOGEL® Disposable Electrodes - Small (1.5cc fill)

OptimA™ Disposable Electrodes - Large (3.0cc fill)

$64.00

OptimA™ Disposable Electrodes - Large (3.0cc fill)

IOMED's Buffered Technology Satisfying the...
OptimA™ Disposable Electrodes - Medium (2.0cc fill)

$64.00

OptimA™ Disposable Electrodes - Medium (2.0cc fill)

IOMED's Buffered Technology Satisfying the...
OptimA™ Disposable Electrodes - Small (1.5cc fill)

$64.00

OptimA™ Disposable Electrodes - Small (1.5cc fill)

IOMED's Buffered Technology Satisfying the...
TransQE® Disposable Electrodes - Medium (2.5-3cc fill)

$64.00

TransQE® Disposable Electrodes - Medium (2.5-3cc fill)

Two Shapes •  Rectangular and...
TransQE® Disposable Electrodes - Small (1.5-2cc fill)

$64.00

TransQE® Disposable Electrodes - Small (1.5-2cc fill)

Two Shapes •  Rectangular and...
TransQ® FLEX Disposable Electrodes - (2.5cc fill)

$64.00

TransQ® FLEX Disposable Electrodes - (2.5cc fill)

Surrounds Highly Contoured Treatment Areas ...

Chattanooga Ionto™ Replacement Lead Wire, each

$25.95

Chattanooga Ionto™ Replacement Lead Wire, each

Empi Dupel® Replacement Lead Wire

$25.95

Empi Dupel® Replacement Lead Wire

IOMED® Phoresor TL7 Lead Wire Cable: For PM850 & PM900 Systems

$25.95

IOMED® Phoresor TL7 Lead Wire Cable: For PM850 & PM900 Systems

  Twin Lead Assembly For use only with PM850 or PM900 Iontophoresis Drug Delivery Systems.    
Vial Venting System

$5.95

Vial Venting System

REFERENCES

1.  Hartley. A. 1990. Practical Joint Assessment. Mosby Year Book. St. Louis.

2.                 Hoppenfeld, S. 1976. Physical Examination of the Spine and Extremities. Appleton-Cenlury-Crofts. New York.

3.                 Kendall, F.  1993. Muscle Testing and Enaction. 4th ed. Williams and Wilkins. Baltimore.

4.                 Magee. D.J. 1992. Orthopedic Physical Assessment. 2nd ed. W.B. Saunders. Philadelphia.

5.                 Warwick. R. and Williams. P. 1983. Gray's Anatomy. 35th British Ed. W.B. Saunders. Philadelphia.


 

Enter Balego Store 

 


Copyright © 2024 Balego & Associates, Inc.
(800) 322-2781
We can answer any questions you may have before you order.
"Providing the Products You Want and the Services You Need Since 1984"