IONTOPHORESIS PROCEDURE

IMPORTANT: See Phoresor System and electrode instruc­tion guides for indications, contraindications, warnings, pre­cautions and directions for use.

1.                 Clean skin is absolutely necessary to minimize or elimi­nate skin irritation. Clean both electrode sites vigorously with an alcohol wipe prior to applying electrodes to remove dry skin, salts and oils. Excess hair may be trimmed with scissors or electric clippers. Do not shave skin. Doing so may result in excessive irritation or burns.

2.        Prepare electrodes according to package instructions.

3.                 Place the drug electrode over the involved tendon at its most tender point.

4.        The dispersive pad may be placed proximal or distal to the drug electrode, over a major muscle (e.g.. biceps, triceps or trapezius). Never tape, bind or compress either elec­trode in any way. Properly prepared drug electrodes and dispersive pads do not require added fixation on properly prepared skin.

5.        Do not allow the patient to extend or flex the shoulder or to press on or lean against the electrodes during treatment. Also, be sure the patient's clothing does not press on either electrode in any way. This prevents circuit breaks and minimizes the possibility of excessive irritation or burns.

6.        Set treatment dosage (for TransQ. electrodes) accord­ing to the package instructions.

Treat every other day. Usually, no more than three to six treatments are required, but there is no contraindication for additional treatments.

IOGEL® Disposable Electrodes - Large (3.5cc fill)

$64.00

IOGEL® Disposable Electrodes - Large (3.5cc fill)

IOGEL® Disposable Electrodes - Medium (2.5cc fill)

$64.00

IOGEL® Disposable Electrodes - Medium (2.5cc fill)

IOGEL® Disposable Electrodes - Small (1.5cc fill)

$64.00

IOGEL® Disposable Electrodes - Small (1.5cc fill)

OptimA™ Disposable Electrodes - Large (3.0cc fill)

$64.00

OptimA™ Disposable Electrodes - Large (3.0cc fill)

IOMED's Buffered Technology Satisfying the...
OptimA™ Disposable Electrodes - Medium (2.0cc fill)

$64.00

OptimA™ Disposable Electrodes - Medium (2.0cc fill)

IOMED's Buffered Technology Satisfying the...
OptimA™ Disposable Electrodes - Small (1.5cc fill)

$64.00

OptimA™ Disposable Electrodes - Small (1.5cc fill)

IOMED's Buffered Technology Satisfying the...
TransQE® Disposable Electrodes - Medium (2.5-3cc fill)

$64.00

TransQE® Disposable Electrodes - Medium (2.5-3cc fill)

Two Shapes •  Rectangular and...
TransQE® Disposable Electrodes - Small (1.5-2cc fill)

$64.00

TransQE® Disposable Electrodes - Small (1.5-2cc fill)

Two Shapes •  Rectangular and...
TransQ® FLEX Disposable Electrodes - (2.5cc fill)

$64.00

TransQ® FLEX Disposable Electrodes - (2.5cc fill)

Surrounds Highly Contoured Treatment Areas ...

Chattanooga Ionto™ Replacement Lead Wire, each

$25.95

Chattanooga Ionto™ Replacement Lead Wire, each

Empi Dupel® Replacement Lead Wire

$25.95

Empi Dupel® Replacement Lead Wire

IOMED® Phoresor TL7 Lead Wire Cable: For PM850 & PM900 Systems

$25.95

IOMED® Phoresor TL7 Lead Wire Cable: For PM850 & PM900 Systems

  Twin Lead Assembly For use only with PM850 or PM900 Iontophoresis Drug Delivery Systems.    
Vial Venting System

$5.95

Vial Venting System

REFERENCES

1.  Hartley. A. 1990. Practical Joint Assessment. Mosby Year Book. St. Louis.

2.                 Hoppenfeld, S. 1976. Physical Examination of the Spine and Extremities. Appleton-Century-Crofts. New York.

3.                 Norkin. C. and Levangie. P. 1992. Joint Structure and Enac­tion 2nded. F.A. Davis, Philadelphia.

4.        Magce, D.J. 1992. Orthopedic Physical Assessment 2nd ed. W.B. Saunders, Philadelphia.

5.                 Warwick, R. and Williams. P. 1983. Gray's Anatomy. 35t_h British Ed. W.B. Saunders. Philadelphia.


 

Enter Balego Store 

 


Copyright © 2024 Balego & Associates, Inc.
(800) 322-2781
We can answer any questions you may have before you order.
"Providing the Products You Want and the Services You Need Since 1984"